Selection of several important components for intermediate frequency induction furnace

 

Why is there a significant price difference for the same model of medium frequency induction furnace on the market? There are many reasons, and today we will focus on analyzing the differences in furnace structure.

1. Furnace shell and induction furnace magnetic yoke

(1) Aluminum shell furnace: Taking a 1-ton aluminum shell furnace as an example, the standard 1-ton aluminum shell furnace weighs 400KG of cast aluminum alloy with a thickness of 40mm. Irregular manufacturers often fail to meet the weight and thickness standards of aluminum shell furnaces in order to save costs.

(2) Steel Shell Furnace: The most important thing for a steel shell furnace is to choose a magnetic yoke. The magnetic yoke should be made of oriented high permeability cold-rolled silicon steel sheets with a thickness of 0.3mm. The silicon steel sheets should adopt a contour structure, and the inner arc surface of the magnetic yoke should be the same as the outer arc surface of the induction coil, so that the magnetic yoke can be tightly attached to the outer side of the induction coil, maximizing the restraint of the coil's outward magnetic field lines. The magnetic yoke is clamped by stainless steel plates on both sides, welded and fixed. Water pipes are added to both sides of the magnetic yoke for water cooling.

Non regular manufacturers have strong arbitrariness in choosing magnetic yokes, using waste, non oriented magnetic yokes, and even using silicon steel sheets removed from transformers to make magnetic yokes.

Induction Furnace Magnetic Yoke

2. Copper tube

Induction furnace assembly copper coils are the core of induction melting furnaces, and the price of induction furnace assembly copper coils varies greatly depending on whether they are made of cold extruded copper pipes or cast copper pipes. A cold extruded copper tube with a rectangular cross-section of T2 and a wall thickness of 6mm should be used, which not only ensures the rigidity of the coil, but also has the maximum conductive cross-section. There is a certain gap between the turns of the coil. When applying refractory adhesive to the coil, the refractory adhesive should penetrate into the gap to strengthen the adhesion of the adhesive on the coil. After the refractory adhesive is built, the inner surface should be smooth to facilitate the removal of the furnace lining and protect the coil. Several stainless steel water-cooled rings should be added to the upper and lower ends of the coil to increase overall rigidity and facilitate heat dissipation.

Some informal manufacturers choose copper pipes made of cast copper or T3, which have poor conductivity and are prone to cracking and leakage. Therefore, caution should be taken when purchasing.

Induction Furnace Assembly Copper Coil